'[PIC:] New version of PIC ICD2 clone'
2004\08\02@042558 by MK

flavicon
face
New version of PIC ICD2clone with improved design

www.mcu.cz/images/articles/products/PIC_ICD2_1.jpg
http://www.mcu.cz/images/articles/products/PIC_ICD2_v23_en.pdf

old version at
http://www.mcu.cz/modules/news/article.php?storyid=430

secure order page
https://www.2checkout.com/cgi-bin/buyers/orderpage.2c?sid=127184

regards
Kosta

--
http://www.piclist.com#nomail Going offline? Don't AutoReply us!
email spam_OUTlistservTakeThisOuTspammitvma.mit.edu with SET PICList DIGEST in the body

2004\08\02@113218 by Bob Axtell

face picon face
I am now building up this version. Looks good so far.
I'll post the results when it is finally put together.
(next 48 hrs).

--Bob

MK wrote:

{Quote hidden}

--

Replier: Most attachments rejected
      --------------
        Bob Axtell
PIC Hardware & Firmware Dev
  http://beam.to/baxtell
      1-520-219-2363

--
http://www.piclist.com#nomail Going offline? Don't AutoReply us!
email listservspamKILLspammitvma.mit.edu with SET PICList DIGEST in the body

2004\08\02@120820 by Joan Ilari

flavicon
face
Still without USB interface .... :-((

  Joan Ilari

  Barcelona (Spain)

================================================================
 ... I've seen things you people wouldn't believe. Attack ships
 on fire off the shoulder of Orion. I watched C-beams glitter
 in the dark near Tannhauser Gate. All those moments will be
 lost in time, like tears in rain ... Time to die ...

                                    -Blade Runner -
================================================================


{Quote hidden}

--
http://www.piclist.com#nomail Going offline? Don't AutoReply us!
email @spam@listservKILLspamspammitvma.mit.edu with SET PICList DIGEST in the body

2004\08\02@122027 by MK

flavicon
face
> Still without USB interface .... :-((

Why USB interface ???
Microchip USB implementation is slowly comparison to USB/COM interface with FT232B
I'm tested  ICD2 clone with FTDI chips and all is OK :-)
Is easy modify USBCOM converter and ICD2clone to power from USB
But USB power is limited to 500mA :-(

regards
Kosta

--
http://www.piclist.com#nomail Going offline? Don't AutoReply us!
email KILLspamlistservKILLspamspammitvma.mit.edu with SET PICList DIGEST in the body

2004\08\02@135953 by Bob Axtell

face picon face
Joan, its cheaper here in Tucson, AZ to buy the USB to Serial cable-type
adaptors.

I paid $19.00 USD for mine. Works on everything I've tried, and probably
works on this just as well...

--Bob


Joan Ilari wrote:
> Still without USB interface .... :-((
>
>    Joan Ilari


--

Replier: Most attachments rejected
      --------------
        Bob Axtell
PIC Hardware & Firmware Dev
  http://beam.to/baxtell
      1-520-219-2363

--
http://www.piclist.com#nomail Going offline? Don't AutoReply us!
email RemoveMElistservTakeThisOuTspammitvma.mit.edu with SET PICList DIGEST in the body

2004\08\03@202330 by Joan Ilari

flavicon
face
> > Still without USB interface .... :-((
>
> Why USB interface ???

You don't have to have a separate power supply for ICD2 : it is
feeded through USB line.

  Joan Ilari

  Barcelona (Spain)

================================================================
 ... I've seen things you people wouldn't believe. Attack ships
 on fire off the shoulder of Orion. I watched C-beams glitter
 in the dark near Tannhauser Gate. All those moments will be
 lost in time, like tears in rain ... Time to die ...

                                    -Blade Runner -
================================================================

--
http://www.piclist.com hint: To leave the PICList
spamBeGonepiclist-unsubscribe-requestspamBeGonespammitvma.mit.edu

2004\08\05@112134 by Buehler, Martin

picon face
hi kosta
what's the improvement of the new icd2 clone over the old one?
tino

************************************************************************
******************************

>{Original Message removed}

2004\08\05@114752 by MK

flavicon
face
> hi kosta
> what's the improvement of the new icd2 clone over the old one?

- switching PSU for VPP
- cheap PMOSFET switch
- new design PCB
- correct few small mistakes

regards
kosta

--
http://www.piclist.com hint: The list server can filter out subtopics
(like ads or off topics) for you. See http://www.piclist.com/#topics

2004\08\06@084827 by Matt Redmond

picon face
Hi All,

I've been trying to get a PIC talking to a Trimble Lassen SQ GPS module
(3.3v) with no success so far.  Without flaming me for being an idiot <g>,
can anyone tell me by reading the below excerpt from the Lassen manual
whether or not I need to do anything to the signal before feeding into my
PIC?

Note again that the Lassen is a 3.3v device.

The manual says re the serial interface:

As an embedded design, the Lassen SQ GPS provides direct CMOS compatible TTL
level serial I/O. The RX and TX signals on the J2 I/O connector are driven
directly by the UART on the Lassen SQ GPS. Interfacing these signals
directly to a UART in your application circuitry provides direct serial
communication without the complication of RS-232 or RS-422 line drivers.
Note - The serial I/O signals on J2 are TTL level. They are not
inverted or driven to RS-232 levels.

Thanks!

--
http://www.piclist.com hint: The PICList is archived three different
ways.  See http://www.piclist.com/#archives for details.

2004\08\06@090337 by hael Rigby-Jones

picon face
{Quote hidden}

Are you running the PIC at 3.3v as well?  If not you almost certainly need
some level translation.  The PIC's UART input uses a Schmitt trigger and the
minimum input high threshold is 0.8Vdd, or 4volts for a 5v Vdd.  Clearly the
PIC would never see the 3.3 volt output from the GPS.

You certainly need something in the other direction as well (if you are
transmitting data to the GPS).  Injecting a 5volt signal into a 3.3volt part
will cause any input protection diodes to conduct, potentially causing
unexpected operation or possibly even damage.  A simple current limiting
resistor and a schotky diode to clamp the level to the 3.3volt supply would
probably suffice.

Regards

Mike

=======================================================================
This e-mail is intended for the person it is addressed to only. The
information contained in it may be confidential and/or protected by
law. If you are not the intended recipient of this message, you must
not make any use of this information, or copy or show it to any
person. Please contact us immediately to tell us that you have
received this e-mail, and return the original to us. Any use,
forwarding, printing or copying of this message is strictly prohibited.
No part of this message can be considered a request for goods or
services.
=======================================================================

--
http://www.piclist.com hint: The PICList is archived three different
ways.  See http://www.piclist.com/#archives for details.

2004\08\09@110953 by Buehler, Martin

picon face
is there a requirement to do some modifications to the former icd2
clone, to correct the 'few small mistakes', or what will my problems be,
when i've already bought the old version of your icd2 clone?
tino

************************************************************************
******************************

>{Original Message removed}

2004\08\10@102527 by MK

flavicon
face
> is there a requirement to do some modifications to the former icd2
> clone, to correct the 'few small mistakes', or what will my problems be,
> when i've already bought the old version of your icd2 clone?

old version is full functional, but charge pump is no good choice for generating Vpp :-(
'few small mistakes' - this is only corections of names and values of same pasive components

regards
kosta

--
http://www.piclist.com hint: The list server can filter out subtopics
(like ads or off topics) for you. See http://www.piclist.com/#topics

2004\08\10@132337 by Wouter van Ooijen

face picon face
> old version is full functional, but charge pump is no good
> choice for generating Vpp :-(

why not?

Wouter van Ooijen

-- -------------------------------------------
Van Ooijen Technische Informatica: http://www.voti.nl
consultancy, development, PICmicro products

--
http://www.piclist.com hint: The list server can filter out subtopics
(like ads or off topics) for you. See http://www.piclist.com/#topics

2004\08\13@044139 by Buehler, Martin
picon face
does this mean that i will run into troubles, when using the old icd2
clone?
how do I have to modify it to avoid troubles?
(I've just got your icd2 kit recently, but have not yet soldered it
together)
thanx!
tino

************************************************************************
******************************

>{Original Message removed}

2004\08\13@045834 by MK

flavicon
face
> does this mean that i will run into troubles, when using the old icd2
> clone?
> how do I have to modify it to avoid troubles?
> (I've just got your icd2 kit recently, but have not yet soldered it
> together)
> thanx!
> tino

Nothing :-)
Change old kit with new - price is same
Only you must send old kit to may address :-)))

regards
kosta

PS: sorry for may "stupid" english

--
http://www.piclist.com hint: To leave the PICList
piclist-unsubscribe-requestEraseMEspam.....mitvma.mit.edu

More... (looser matching)
- Last day of these posts
- In 2004 , 2005 only
- Today
- New search...